• 产品-20.jpg

JCB6536-05Z Fully Automatic Distillation Range Tester


Applicable standards: GB/T 6536-2010, ASTM D86, ASTM D 850, ASTM D 1078 – IP 195, ISO 3405—Methods for Determining the Atmospheric Distillation Characteristics of Petroleum Products; GB/T 255—Method for Determining the Distillation Range of Petroleum Products; GB/T 7534-2004—Determination of the Boiling Range of Volatile Organic Liquids for Industrial Use; determination of the distillation range of methanol and alcohol products; GB/T 615-2006—Determination of the Boiling Range of Chemical Reagents; GB/T 3146.1-2010—Determination of the Distillation Range of Industrial Aromatics and Benzene Products; GB/T 26984-2011—Determination of the Distillation Range of Crude Oil; GB/T 2282—Determination of the Distillation Range of Coking Light Oil Products; GB/T 18255-2000—Determination of the Distillation Range of Coking Viscous Oil Products—designed and manufactured in accordance with these standard requirements.


Product Details


  1. Standards Applied: GB/T 6536-2010, ASTM D86, ASTM D850, ASTM D1078 – IP195, ISO 3405—Methods for Determining the Atmospheric Distillation Characteristics of Petroleum Products; GB/T 255—Method for Determining the Distillation Range of Petroleum Products; GB/T 7534-2004—Determination of the Boiling Range of Industrial Volatile Organic Liquids, including the determination of the distillation range of methanol and alcohol products; GB/T 615-2006—Determination of the Boiling Range of Chemical Reagents; GB/T 3146.1-2010—Determination of the Boiling Range of Industrial Aromatics and Benzene Products; GB/T 26984-2011—Determination of the Distillation Range of Crude Oil; GB/T 2282—Determination of the Distillation Range of Coking Light Oil Products; GB/T 18255-2000—Determination of the Distillation Range of Coking Viscous Oil Products. These standards have been incorporated into the design and manufacture of this equipment.

  2. Temperature measurement range: 0–400°C ±0.01°C; temperature-sensing element: PT100 (original temperature sensor from B+B, Germany)

  3. Volume measurement range: 0–100 ± 0.01 mL (U.S.-imported infrared graduated cylinder reading system), with a step size of 0.01 mL per increment.

  4. Distillation rate: 0–10 mL/min, arbitrarily adjustable according to experimental requirements; the standard rate is 4–5 mL/min.

  5. Condenser temperature range: 0–80 ± 1 °C; compressor‑based cooling (imported from Danfoss, Germany). The bath is filled with antifreeze and equipped with a circulation system, ensuring uniform temperature control; the antifreeze is non‑volatile and non‑flammable, and does not require replacement even after prolonged use.

  6. Temperature control range of the graduated cylinder: 0–80 °C; the recovery chamber is equipped with a fan to ensure uniform temperature distribution and excellent sealing, preventing air convection.

  7. Display Function: A 10-inch color LCD touch screen with a fully Chinese-language operating interface; volume and temperature parameters can be set arbitrarily; the experimental process displays a temperature–volume curve, and records the values at each set point; additionally, it features access‑control functionality to effectively prevent non‑specialist users from modifying the instrument’s critical settings.

  8. Operating System: Windows XP; the software is upgradable, with Dairite operating software.

  9. Safety Features: cold bath liquid-level sensor protection, automatic nitrogen fire suppression, over-temperature protection, over-volume protection, over-power protection, start-up inhibition when no graduated cylinder is present, and sensor‑failure alert.

  10. Error Correction: Users can set parameters according to actual conditions, enabling rapid calculation of measurement results and associated errors. If the measured result exceeds the allowable tolerance, the instrument will automatically initiate a re‑measurement. Calibration must be performed using standard oil samples to correct for errors.

  11. Data Acquisition: The instrument automatically saves over a thousand measurement results and features a built-in 20‑column dot‑matrix micro thermal printer, delivering quieter, faster, and clearer printing. Experimental results can be printed automatically.

  12. Correction Function: Allows calibration of atmospheric pressure, vapor temperature, sensors, and graduated cylinders.

  13. Interface Outputs: USB/RS‑232 communication interface for interfacing with a host computer, facilitating integration into a centralized management system. The instrument can be connected to a LIMS system and can also be operated via a PC or a touch screen; (additional charge applies for the PC option).

  14. Voltage and Power: AC 220 V ±10%, 50 Hz; Power: 1200 W. A reliable grounding wire is required. Operating temperature range: 10°C to 30°C.

  15. Dimensions and Weight: 440 × 500 × 640 mm and 65 kg


Production workshop


Aluminum recycling

Aluminum recycling

Aluminum recycling

Aluminum recycling

Aluminum recycling

Application Cases


Aluminum recycling

Aluminum recycling

Aluminum recycling

Aluminum recycling

Certificate of Honor


Core Supplier Certificate

Core Supplier Certificate

Occupational Health and Safety Management System Certification

Occupational Health and Safety Management System Certification

Environmental Management System Certificate

Environmental Management System Certificate

Quality Management System Certification

Quality Management System Certification

Tianjin Dongfang Credit Rating Certificate

Tianjin Dongfang Credit Rating Certificate

Bank Account Opening License

Bank Account Opening License

Related products


Leave a message


Welcome to leave an online message for inquiries and please keep your contact information up to date. We will get in touch with you as soon as possible.

%{tishi_zhanwei}%