JCB33400-02 Total Contaminant Content Analyzer for Diesel Fuel
Category:
It is used to determine the total contaminant content in middle‑distillate fuels, diesel fuel with a fatty acid methyl ester (FAME) volume fraction not exceeding 30%, and pure FAME (BD100), as specified by the relevant standards. It is also suitable for samples with a kinematic viscosity of no more than 8 mm²/s at 20°C or no more than 5 mm²/s at 40°C, and for samples with a total contaminant content ranging from 12 mg/kg to 30 mg/kg; precision requirements are stipulated for these conditions. The instrument may also be applied to samples whose total contaminant content falls outside this range, though its precision is not specified in such cases. It is the preferred choice for refineries and testing laboratories seeking to measure the total contaminant content in diesel fuel. The device features a long service life, low noise, minimal vibration, a compact footprint, easy maintenance, an attractive appearance, and straightforward operation.
Contact :
Product Details
It is used to determine the total contaminant content in middle‑distillate fuels, diesel fuel with a fatty acid methyl ester (FAME) volume fraction not exceeding 30%, and pure FAME (BD100), as specified by the relevant standards. It is also suitable for samples with a kinematic viscosity of no more than 8 mm²/s at 20°C or no more than 5 mm²/s at 40°C, and for samples with a total contaminant content ranging from 12 mg/kg to 30 mg/kg; precision requirements are stipulated for these conditions. The instrument may also be applied to samples whose total contaminant content falls outside this range, though its precision under such circumstances is not specified. It is the preferred choice for refineries and testing laboratories seeking to measure the total contaminant content in diesel fuel. The device features a long service life, low noise, minimal vibration, a compact footprint, easy maintenance, an attractive appearance, and straightforward operation.
Technical Specifications:
1. Power supply: AC 220 V ±10%, 50 Hz
2. Vacuum level: absolute pressure 2 kPa to 5 kPa
(The vacuum pressure gauge has a range of approximately -0.95 to -0.98 bar.)
3. Vacuum regulation method: adjustment via a stainless steel needle valve
4. Glass fiber filter membrane: Φ47 mm; pore size 0.7 μm, used for sample filtration.
5. Solvent filtration membrane: Φ47 mm; pore size 0.45 μm, for reagent filtration.
6. Timer: 0–99H99M
7. Sand-core filtration apparatus: funnel volume 300 ml, receiving flask volume 1000 ml
8. Safety flask: 1000 ml top‑mouth filtration flask
9. Vacuum pump: rotary vane vacuum pump, pumping speed: 2 L/s
10. Buffer tank capacity: 5 L
11. Operating environment: relative humidity ≤ 80%, temperature 0–45°C